For tank venting, inline and filter drying Heatable filter housings and pipe heaters
Drying gas filters after the integrity test – directly in the housing or at a separate drying station.
HZG heatable filter housings dry the filter in the heated filter bell. The RHZ pipe heater heats the gas flow for drying – inside or outside the plant, depending on the set-up. Both solutions use self-regulating PTC heating elements and need no elaborate external temperature control.
PDFBrochure filter housingsEnglish · 9 pages · 4.4 MBPDFBrochure RHZ pipe heaterEnglish · 8 pages · 1.6 MB

Heatable filter housings HZG
After the Water Flow Test (Water Intrusion), the gas filter dries directly in the heated filter bell – without removing the filter element. Self-regulating PTC heating elements provide the heating without an elaborate external temperature control.
The double-wall housings are made of ground and electropolished stainless steel 1.4404 (316L). The Code 7 adapter accepts suitable filter cartridges from various manufacturers.
- High-quality surfaces: inside Ra < 0.8 µm, outside Ra < 1.2 µm
- Integrated test connection: Stäubli valve nipple for venting, draining condensate and connecting the filter integrity tester
- Flexible connections: Tri-Clamp connections depending on the version; optional additional connection for a Pt100 sensor
- Documentation included: drawing, pressure vessel certificate, 3.1 material certificate, performance test and electrical test according to DIN VDE 0701-0702 drawing, pressure vessel certificate and 3.1 material certificate; on request a test parameter list for your filter element
The versions
Housings for different installation situations – with suitable sizes and connections, also customised.
5″
Heatable filter housing for 5″ filter cartridges
10″
Heatable filter housing for 10″ filter cartridges
20″
Heatable filter housing for 20″ filter cartridges
Pipe heater RHZ – inline or as a drying station
The RHZ pipe heater dries gas filters after the integrity test with a heated gas flow. Two applications are available:
Inline the RHZ pipe heater is installed directly into the pipeline between two pipe ends. It heats the gas flowing through to dry the filter. The filter element stays in the filter housing.
At the separate drying station, gas flows through the filter capsules or cartridges in the reverse direction to normal operation. This carries residual water out through the inlet side.
- Self-regulating heating: PTC heating elements without an elaborate external temperature control
- Suitable media: purified compressed air or nitrogen
- Separate drying station: RHZ-02 on a pedestal with a suitable connection set-up for filter capsules or filter cartridges.
Example values from the documented drying tests
*Test set-up with an externally connected RHZ via silicone tube. The times given apply to the documented tests; the drying time depends on the filter element and set-up.


The two set-ups
The RHZ pipe heater dries gas filters either permanently installed in the pipeline or at a separate drying station.
Permanently installed in the pipeline
The RHZ-02 is installed between two pipe ends upstream of the filter housing – either as a single unit or with two RHZ-02 units installed in parallel.
Outside the plant
Gas flows through the filter capsules or cartridges in the reverse direction to normal operation, carrying residual water out through the inlet side.


Further filter housings and filter adapters
In addition to heatable filter housings, we supply single and multi-cartridge filter housings as well as matching filter adapters.

Single filter housings
We offer single filter housings in all common designs and sizes – for filter cartridges from 2.5″ to 40″ and with various filter adapters.

Filter adapters
Filter adapters are available in different designs, for example as L, T or I versions. Various cartridge connections are available, such as Code 7, Code 2, Code 3 or DOE. We configure additional connections for integrity testing to suit your requirements.


Multi-cartridge filter housings
Multi-cartridge filter housings hold several filter cartridges in parallel. They are used when higher flow rates, larger batches or more filtration area are required – for example for tank venting. We match the number of cartridges and the connections to your process.
Matching accessories
Thermowells for Pt100 sensors
So that the sensor can be calibrated outside the housing: Pt-TH-55-TC 1,5 (TC 50.5, 55 mm) and Pt-TH-70-TC 0,5 (TC 25, 70 mm).
Temperature indicators (TCU)
Temperature indicators with switching or current output for integration into your plant monitoring. They are mounted with a TC clamp on the housing dome.
Filter integrity testers
Connect the filter integrity tester for the Water Flow Test (Water Intrusion) directly via the Stäubli nipple on the inlet elbow.
All details in the brochures
Heatable filter housings and the RHZ pipe heater – compact as PDF downloads.
The right solution for your plant
Do you need a heatable filter housing or a pipe heater? We will advise you on the version, connections and integration into your plant.
Mon–Thu 9 am–5 pm · Fri 9 am–3 pm